UTP Maintenance, flux-cored wire, hardfacing

UTP 402-O self-shielded flux-cored wire

EN ISO classification14700 T Z Fe10
Price on request
Give us the diameter and the quantity, we will quote during working hours

Spawlab is the data controller. We will use your data only for replying to this price enquiry. See the privacy policy for details.

Authorised distributorvoestalpine Böhler Welding
Shipping in 24 hfrom the warehouse in Krotoszyn
Data sheetcomposition, properties, specifications
Wire selectionhelp from a welding engineer
Manufacturer data sheet
Application

What UTP 402-O self-shielded flux-cored wire is used for

UTP 402-O is a self-shielded metal cored wire recommended for build-up, crack repair and buffer layers laid before hardfacing.

It needs no shielding gas, which makes work outdoors and in wind simpler, and the shielding comes from the core, so no cylinder or regulator is needed at the station. The wire rebuilds shafts, rollers, screws, blades and surfaces working under abrasion.

  • Classification EN ISO: 14700 T Z Fe10
  • Shielding: self-shielded, no shielding gas
  • Diameters: 1.6 / 2.4 / 2.8 mm
  • Hardness of deposit: 160 HB

Check how many layers you need to reach the target hardness, the first layer always mixes with the base material. Work with fume extraction, self-shielded wires smoke far more than gas shielded ones. Check the polarity before you start, self-shielded wires often run differently from solid wires. Match the diameter to the thickness and the position, thinner wires are easier to control in constrained positions.

Fits

For which materials and machines

Base materials

Material group: hardfacing. The exact grades and thicknesses are in the manufacturer data sheet, and for an unusual joint call us, we will pick the filler metal.

Process and machines

Flux-cored wire, works on any sound machine for this process: welders.

Used welders New welders Ask us to help you choose
From the same group

Other wires for this application

All: UTP hardfacing consumables