Böhler Welding, solid MIG/MAG wire, mild and low-alloy steels

Pipeshield X 90 solid MIG/MAG wire

EN ISO classification16834-A G 55 6 M21 Mn3Ni1Mo G 55 4 C1 Mn3Ni1Mo
AWS classificationA5.28 / SFA-5.28 ER90S-G
Shielding gasC1: 100 % CO2, M21: Ar with 15 to 25 % CO2
Price on request
Give us the diameter and the quantity, we will quote during working hours

Spawlab is the data controller. We will use your data only for replying to this price enquiry. See the privacy policy for details.

Authorised distributorvoestalpine Böhler Welding
Shipping in 24 hfrom the warehouse in Krotoszyn
Data sheetcomposition, properties, specifications
Wire selectionhelp from a welding engineer
Manufacturer data sheet
Application

What Pipeshield X 90 solid MIG/MAG wire is used for

Pipeshield X 90 is a solid wire for mild steel. It suits welding mild and low-alloy steels, fine-grained grades included, in structural steelwork, on tanks, piping and series production.

It joins grades such as S460N, S460M, S460NL, S460ML, S460Q, S555Q and S460QL together with their equivalents. You can weld in all positions, including vertical up and overhead, and the wire runs well on robot and mechanised stations.

  • Classification EN ISO: 16834-A G 55 6 M21 Mn3Ni1Mo G 55 4 C1 Mn3Ni1Mo
  • AWS classification: A5.28 / SFA-5.28 ER90S-G
  • Shielding gas: M21, C1
  • Diameters: 1.0 mm

On thicker parts and in a cold workshop plan preheating to cut the risk of cold cracking. Watch the wire stick-out from the contact tip, too long a one lowers the arc voltage and worsens the fusion. Set the gas flow so the pool is covered over the whole length of the bead, and shield the station when you work in wind.

Manufacturer datasheet

Chemical composition and properties from the manufacturer datasheet

Datasheet PDF

Typical all-weld metal values from the voestalpine Böhler Welding datasheet, edition 10/2023. Manufacturer minimum in brackets. Values depend on the heat treatment condition and shielding gas given for each row and do not replace testing of your joint according to your WPS.

Chemical composition, wt.-%
CSiMnNiMo
0,080,601,80,90,30
Welding data and approvals
Polaritydirect current, electrode positive (DC+)
Shielding gas to EN ISO 14175M2
Datasheet edition10/2023
Mechanical properties of the all-weld metal, typical values
Condition Yield strength Re, MPa Tensile strength Rm, MPa Elongation A, % Impact energy KV, J at -40 °C Impact energy KV, J at -60 °C
u1 620 (min. 550) 700 (min. 640) 23 (min. 18) 110 (min. 70) 60 (min. 47)
u2 590 (min. 550) 680 (min. 640) 22 (min. 18) 80 (min. 47) -
  • u: untreated, as welded, shielding gas Ar + 15, 25% CO 2
  • u2: untreated, as welded, shielding gas 100% CO2
Fits

For which materials and machines

Base materials
  • S460N
  • S460M
  • S460NL
  • S460ML
  • S460Q
  • S555Q
  • S460QL
  • S550QL
  • S460QL1
  • S550QL1
  • P460NH
  • P460NL1
Process and machines

Solid MIG/MAG wire, works on any sound machine for this process: welders. Shielding gas: C1: 100 % CO2, M21: Ar with 15 to 25 % CO2.