Böhler Welding, stick electrode, mild and low-alloy steels

BÖHLER FOX BVD 85 stick electrode

EN ISO classificationEN ISO 2560-A: E 46 5 1Ni B 4 5 H5, EN ISO 2560-B: E5545-P2 A U H5
AWS classificationAWS A5.5 / SFA-5.5: E8018-GH4R, AWS A5.5 / SFA-5.5: E8045-P2H4R, AWS A5.5M: E5518-GH4R, AWS A5.5M: E5545-P2H4R
ApprovalsTÜV (03531.), CE
Price on request
Give us the diameter and the quantity, we will quote during working hours

Spawlab is the data controller. We will use your data only for replying to this price enquiry. See the privacy policy for details.

Authorised distributorvoestalpine Böhler Welding
Shipping in 24 hfrom the warehouse in Krotoszyn
Data sheetcomposition, properties, specifications
Wire selectionhelp from a welding engineer
Manufacturer data sheet
Application

What BÖHLER FOX BVD 85 stick electrode is used for

BÖHLER FOX BVD 85 is a basic coated electrode with a very low hydrogen content in class H5, meant for vertical-down welding of large diameter pipelines and for structural work. The manufacturer recommends it for filler and cover passes. The deposit combines high strength with toughness held down to -50 degrees C, and the material is qualified for sour gas service after the HIC test to NACE TM-02-84, with SSC test values available.

The base steels cover L290NB to L450NB, L290MB to L450MB, P235GH to P295GH as well as S235J2 and S355J2. The deposit is extremely crack resistant, which on heavier walls reduces the risk of cold cracking. The design of the coating makes striking easier and suppresses start porosity, so the electrode stands up to field conditions. With this technique you lay down 80 to 100 percent more weld metal in the same time than welding vertical-up.

  • Classification EN ISO 2560-A: E 46 5 1Ni B 4 5 H5
  • Classification EN ISO 2560-B: E5545-P2 A U H5
  • AWS classification A5.5 / SFA-5.5: E8045-P2H4R and E8018-GH4R
  • Coating: basic
  • Current: DC+
  • Diameters: 3.2 / 4.0 mm
  • Lengths: 350 mm
  • Approvals: TÜV (03531.), CE

Dry the electrodes to the data sheet before work and take out of the oven only what you will use on the shift, because class H5 applies to a dry coating. Guide the electrode fast, with a slight lead angle, and keep the arc short. In low ambient temperatures preheat the pipe to the WPS, so that the stresses in the root are reduced. For sour gas, choose the base material and the procedure according to the requirements of the plant owner.

Manufacturer datasheet

Chemical composition and properties from the manufacturer datasheet

Datasheet PDF

Typical all-weld metal values from the voestalpine Böhler Welding datasheet, edition 10/2023. Manufacturer minimum in brackets. Values depend on the heat treatment condition and shielding gas given for each row and do not replace testing of your joint according to your WPS.

Chemical composition, wt.-%
CSiMnNi
0,050,41,10,9
Welding data and approvals
ApprovalsTÜV (03531.), CE
Datasheet edition10/2023
Fits

For which materials and machines

Base materials
  • L290NB do L450NB
  • L290MB do L450MB
  • P235GH do P295GH
  • S235J2
  • S355J2

current: DC+

Process and machines

Stick electrode, works on any sound machine for this process: welders.

Used welders New welders Ask us to help you choose
From the same group

Other wires for this application

All: Stick electrodes